MobiRack enclosures are available in 5U, 11U, 14U and 16U configurations. The enclosures offer an impressively rich array of options from visual choices (colors, labels, custom stenciling) to functional (removable rack, choice of handles, trays, drawers, shelves, shocks, storage pouches, coupling catches, support rails, etc.) to environmental controls like airtight/watertight or humidity indicator gauges. When you combine all of this with SGI's custom-built Intel and AMD-based half depth servers, storage systems, power distribution infrastructure (including power distribution units (PDUs), batteries and rectifiers) and SGI's build-to-order business model, one can clearly see the maximized configuration flexibility that is available from SGI.
MobiRack™ enclosures are available in compact (5U and 11U) and midrange (14U and 16U) mobile data center configurations. MobiRack’s mobility and robust features strengthen Rackable’s broad portfolio of deployed data center products.
Enclosure Model
Supported Server Models
No. of Servers/Enclosure
No. of Boards/Enclosure
No. of Processor (& Cores)/Enclosure
Max. No. of 3.5" Drives/Enclosure
Server Mounting
Thermal Management
Enclosure Input Power
Server Input Power
Back Up DC Power Infrastructure Option
Cable Management
Enclosure Weight Support
Peripheral Support Options (Switches, JBOD)
MR1000-5U
All half depth 1U & 2U Intel or AMD based server models with wide selection of dual socket server boards
Up to 5x1U or 2x 2U
Up to 5
Up to 10 (40)
Up to 10 SAS/SATAII DAS Drives (10TB)
Fixed via brackets (standard)
Front to back cooling up to 95°F ambient temperature. Servers must have internal cooling fans & enclosure lids must remain removed for proper operation
Expected nominal 110VAC
AC only
No due to space limitations
Front (IO) or rear cabling (Power)
Up to 340 Lbs
Yes. Consult with factory on tested configurations and weight
MR1000-11U
All half depth 1U & 2U Intel or AMD based server models with wide selection of dual socket server boards
Up to 11x1U or 5x 2U
Up to 11
Up to 22 (88)
Up to 25 SAS/SATAII DAS Drives (25TB)
Fixed via brackets (standard)
Front to back cooling up to 95°F ambient temperature. Servers must have internal cooling fans & enclosure lids must remain removed for proper operation
Expected nominal 110VAC with PDU support option at enclosure level
AC or DC depending on config.
Yes. Rectifiers, Battery Back Up Unit (BBU)
Front (IO) or rear cabling (Power)
Up to 340 Lbs
Yes. Consult with factory on tested configurations and weight
MR1000-14U
All half depth 1U & 2U Intel or AMD based server models with wide selection of dual socket server boards
Up to 14x1U or 7x 2U
Up to 14
Up to 28 (112)
Up to 35 SAS/SATAII DAS Drives (35TB)
Fixed via brackets (standard)
Front to back cooling up to 95°F ambient temperature. Servers must have internal cooling fans & enclosure lids must remain removed for proper operation
Expected nominal 110VAC with PDU support option at enclosure level
AC or DC depending on config.
Yes. Rectifiers, Battery Back Up Unit (BBU)
Front (IO) or rear cabling (Power)
Up to 340 Lbs
Yes. Consult with factory on tested configurations and weight
MR1000-16U
All half depth 1U & 2U Intel or AMD based server models with wide selection of dual socket server boards
Up to 16x1U or 8x 2U
Up to 16
Up to 32 (128)
Up to 40 SAS/SATAII DAS Drives (40TB)
Fixed via brackets (standard)
Front to back cooling up to 95°F ambient temperature. Servers must have internal cooling fans & enclosure lids must remain removed for proper operation
Expected nominal 110VAC with PDU support option at enclosure level
DC. Contact Factory for AC support
Yes. Rectifiers, Battery Back Up Unit (BBU)
Front (IO) or rear cabling (Power)
Up to 300 Lbs
Yes. Consult with factory on tested configurations and weight